261704 Miller Breathing Tube Assembly (Face Shield PAPR)
Passar dessa system
| System | Kompatibilitetsstatus | Belägg |
|---|---|---|
| Miller Face Shield PAPR | T2 Manufacturer-listed part |
|
Specifikationer
| Blower connection | Align pins on the blower-end connector with channels in the blower receptacle, insert until snug, then turn connector 1/8 turn clockwise (Section 6-5) |
|---|---|
| Helmet connection | While pressing the blue locking tabs in, push the rectangular connector onto the helmet air inlet until it locks (Section 6-5) |
| Cover | FR Breathing Tube Cover (265312) available separately |
| Maintenance | Inspect breathing tube and replace if damaged or if inside of tube is dirty (Section 7) |
STOCKED BY — SUPPLIER CROSS-REFERENCE
Stocked by
- Baker's Gas & Welding Supplies US
- Cyberweld US
- Welder Supply US
- Weldfabulous US
- Weldready CA
- Welding Supplies from IOC US
No listed suppliers for this region — see the supplier directory.
See the full supplier directory for all regions and evidence notes.
Listing ≠ endorsement. Confirm availability, approval status and source evidence before purchase or regulated workplace use.
Postens källor
Evidence — dated sources
- [01] www.millerwelds.com manufacturer manual OM-288359A Section 6-5 (p.17), Section 7 (p.24), Section 10 (p.31). 2026-07-06