I18N Interface traduite automatiquement. Les données des pièces, les spécifications et les éléments de preuve restent en anglais ; la version anglaise fait foi.

SEC 01 // FICHE SYSTÈME

RPB PX5 PAPR

Verified against primary source · 2026-07-06 current

RPB's (GVS-RPB) modular powered air-purifying respirator: a belt- or backpack-mounted blower/filter unit (PX5) that is NOT itself the headtop. The PX5 draws ambient air through a snap-in filter cartridge (HE / OV-AG-HE / Multi-Gas) fitted directly into the PX5 housing, then pushes filtered air up a separate breathing tube into whichever approved loose-fitting headtop the wearer has selected (Z-Link, Z-Link+, Z-Link Radiant Heat, Z4, Z3, T-Link, T200, T300 Sterile, Nova 3). Approved by NIOSH (US) and certified to EN 12941 (UK/EU) and AS/NZS 1716:2012 (AU/NZ).

Classe d'homologation

Approval standards, classes and regions
StandardClassRegion
NIOSH 42 CFR 84Powered Air-Purifying Respirator (PAPR) Fan UnitUS
EN 12941:2023TH3/2 (with Z-Link) / TH3 (T-Link, T200, T300 Sterile) / TH2 (Z4) — see generationNoteUK/EU
AS/NZS 1716:2012BMP# 714303AU/NZ
Avertissement générations et numéros de pièce : Architecture: the PX5 is one of three "required components" of a complete approved system — (1) PX5 blower/filter unit, (2) breathing tube assembly, (3) approved respirator headtop (RPB CE instruction manual Form 7.20.569 Rev 5, p.9, "Make sure you have a complete system"). The filter cartridge (HE 03-892/03-892-P, OV/AG/HE 03-893/03-893-A2, or Multi-Gas 03-894/03-894-ABE/03-895-ABEK) snaps into the PX5 housing itself, not into the headtop — the headtop only carries the visor/cape/face-seal and the far end of the breathing tube. Two breathing-tube part numbers exist because the coupler differs: 04-831 fits Z-Link, Z4, Nova 3 and T-Link; 04-832 is Z3-specific (PX5 Technical Data Sheet Form 7.20.452 R10, p.3). Regional split: NIOSH-market headtops (Z3, Nova 3) are NOT sold/approved in CE & AS/NZS markets — the Nov-2022 PX5 Technical Data Sheet (Form 7.20.452 R10, p.1) explicitly separates "Compatible with NIOSH Markets: Nova 3, T200, T-Link, Z-Link, Z3, Z4" from "CE & AS/NZS Markets: T200, T-Link, Z-Link, Z4" — Z3 and Nova 3 have no CE/AS-NZS filter or breathing-tube SKU equivalent. The CE instruction manual's own "Apparatus Classification and Protection Factor" table (Form 7.20.569 Rev 5, p.6, Table 1.1) lists five CE/AS-NZS headtop rows (Z-Link, T-Link, Z4, T200, T300 Sterile) each with its own EN 12941 class and nominal protection factor: Z-Link = TH3/2 (APF 500/50), T-Link = TH3 (APF 500), Z4 = TH2 (APF 50), T200 = TH3 (APF 500), T300 Sterile = TH3 (APF 500, all combination filters except 03-896-ABEKHg). Z-Link+ is marketed as PX5-compatible on the current product page but does not appear as its own row in that table — likely grouped under the Z-Link classification, but this is not confirmed by a primary source and should not be assumed without checking the Z-Link+ headtop's own instruction manual. Known cross-document inconsistency (RPB's own documents disagree, flagging per the ESAB precedent): the Nov-2022 PX5 Technical Data Sheet (Form 7.20.452 R10) prints the certification block as "EN12941:1998 +A2:2008 TH3/2 P R SL". The June-2025 PAPR Filters Technical Data Sheet (Form 7.20.621 R2) and the current (©2025) CE instruction manual (Form 7.20.569 Rev 5, cover page and p.5 "Equipment Marking") both cite "EN12941:2023 TH3" instead — a newer edition of the standard. Treat the 2025 documents as current; the 2022 datasheet's standard-edition reference is stale (RPB has not reissued that data sheet since).

Têtes de protection compatibles

Pièces dans notre base de données

Parts recorded for this system with category and compatibility status
Numéro de piècePièceCatégorieStatut de compatibilité
03-855 PX5 Standard Battery battery T2 Manufacturer-listed part
03-856 PX5 High Capacity Battery battery T2 Manufacturer-listed part
07-765 PX5 Belt (standard, 2 inch) belt T2 Manufacturer-listed part
03-851 PX5 Battery Charger charger T2 Manufacturer-listed part
03-892-P HE (P) Filter - HEPA Particulate (CE & AS/NZS) filter T1 Officially approved
03-892 HE Filter - HEPA Particulate (NIOSH) filter T1 Officially approved
03-893-A2 OV/HE (A2P) Combination Filter (CE & AS/NZS) gas-cartridge T1 Officially approved
03-893 OV/AG/HE Cartridge (NIOSH) gas-cartridge T1 Officially approved
03-894 Multi-Gas Cartridge (NIOSH) gas-cartridge T1 Officially approved
04-831 PAPR Breathing Tube (for Z-Link, Z4, Nova 3 and T-Link) hose T1 Officially approved
04-832 PAPR Breathing Tube (for Z3) hose T2 Manufacturer-listed part
03-890 Pre-filter (10 Pack) prefilter T2 Manufacturer-listed part
03-891 PAPR Spark Arrestor spark-arrestor T2 Manufacturer-listed part

Remarques

Do not confuse the PX5 with RPB's HX5 PAPR (same filter part numbers for HE, but the HX5 is NOT compatible with the OV/Gas cartridges — see the "PAPR filters" datasheet's Compatible-with table, "*The HX5 is not compatible with OV and Gas Filters"). No HX5 records created in this pass — out of scope for this assignment.

Sources de la fiche

Evidence — dated sources
  1. [01] www.gvs-rpb.com manufacturer manual Official PX5 Technical Data Sheet, Form # 7.20.452 R10, Nov 2022. Confirms package part numbers 03-801/03-801-FR/03-802/03-802-FR, NIOSH-vs-CE/AS-NZS headtop market split, full accessories/consumables part-number table (03-890/03-891/03-892/03-893/03-894/03-892-P/ 03-893-A2/03-894-ABE/03-895-ABEK, 03-855/03-856/03-851/03-852, 07-765 belt family, 03-819 flow meter, 03-822 backpack family, 04-831/04-832 breathing tubes), certification block "EN12941:1998 +A2:2008 TH3/2 P R SL", "NIOSH APPROVED", "AS/NZS 1716:2012 BMP# 714303". Archived in repo: sources/rpb-px5-technical-data-sheet-r10-nov2022.pdf. 2026-07-06
  2. [02] www.gvs-rpb.com manufacturer manual Official "PAPR filters" Technical Data Sheet, Form # 7.20.621 R2, June 2025. Certification block updated to "EN12941:2023 TH3". Confirms full CE/AS-NZS filter range including 03-896-ABEKHg (Multi-Gas/Mercury, not covered by a part record yet) and the NIOSH-vs-CE part-number pairing. Archived in repo: sources/rpb-papr-filters-technical-data-sheet-r2-jun2025.pdf. 2026-07-06
  3. [03] www.gvs-rpb.com manufacturer manual GVS-RPB North American Catalog 2022, "PX5 PAPR" section (pp.91-101). Confirms starter-pack contents/part numbers (03-801/802/803 and FR variants), headtop-approval part numbers by headtop family (Z-Link/Z4/T-Link/T200), and a "PX5 PAPR Parts" exploded list (03-810 fan housing, 03-811 belt support mount, 03-812 door cover, 03-813 HEPA(P3) filter door, 03-814 gas filter door, 03-815 battery door assembly incl. 03-818 hinge, 03-817 battery door seal, 03-819 flow meter, 04-831/04-841 breathing tubes, 09-021 power cable). Archived in repo: sources/rpb-gvs-rpb-na-catalog-2022-px5-section.pdf. 2026-07-06
  4. [04] www.gvs-rpb.com manufacturer manual Official PX5 CE instruction manual, Form # 7.20.569 Rev 5 (©2025 GVS-RPB Safety LLC). Cover certification "EN 12941:2023 TH3"; p.6 Table 1.1 "Apparatus Classification and Protection Factor" gives the per-headtop EN 12941 class/APF table cited in generationNote; p.9 "Make sure you have a complete system" describes the 3-component architecture; pp.31-33 give PX5 cleaning/storage and 03-855/03-856 battery specification tables (run times, charge/storage temps, 300+/500+ cycle counts); p.31 names the Belt Support (03-811). Archived in repo: sources/rpb-px5-ce-ui-instruction-manual-r5.pdf. 2026-07-06
  5. [05] www.gvs-rpb.com manufacturer manual Official PX5 NIOSH instruction manual, Form # 7.20.569 Rev 3 (per footer "PX5 PAPR UI R3"). p.4 "Protection Provided and Limitations": "The RPB PX5 is approved by NIOSH... It is approved to be used with the 03-892 High Efficiency (HE) Filter, the 03-893 Organic Vapor/Acid Gas/High Efficiency (OV/AG/HE) Cartridge, and the 03-894 Multi-Gas Cartridge." p.7 confirms the 3-component "complete NIOSH approved respirator system" (Respirator Head-top Assembly + Breathing Tube Assembly + PX5 PAPR). Archived in repo: sources/rpb-px5-niosh-instruction-manual-r3.pdf. 2026-07-06
  6. [06] www.gvs-rpb.com manufacturer page Current official PX5 product page. Lists compatible headtops as "Z-Link, Z-Link+, Z-Link Radiant Heat, Z4, T-Link, T200" — notably omitting Z3 and Nova 3, which the 2022 NIOSH-market datasheet lists as compatible. Possible page-content drift or those headtops being deprioritised on the current NA marketing site; the underlying NIOSH approval documents were not re-checked for a Z3/Nova 3 discontinuation notice. Also the only source found for "Z-Link+" as PX5-compatible by name. 2026-07-06