SEZ 02 // SCHEDA RICAMBIO
15-0099-05 3M Adflo Airflow Indicator
Compatibile con questi sistemi
| Sistema | Stato di compatibilità | Prove |
|---|---|---|
| 3M Speedglas Adflo PAPR | T2 Manufacturer-listed part |
|
Specifiche tecniche
| Function | Ball-float flow-check tool used to verify minimum air flow and test the low-airflow alarm |
|---|---|
| Compatibility | Fits all 3M Adflo PAPR Approved Breathing Tubes except L-122SG (which instead uses adapter 15-0099-21 with rubber adapter 15-0099-20) |
| Not in Table 2 | Not listed in the Table 2 replacement-parts list — sourced from the manual's airflow-check procedure section |
STOCKED BY — SUPPLIER CROSS-REFERENCE
Stocked by
- Airgas US
- Baker's Gas & Welding Supplies US
- Cyberweld US
- Enviro Safety Products US
- 1StopWeldingShop UK
- Engweld UK
- Schweiss-Shop.de DE
- Apex Welding Safety AU
- Weldready CA
- 3M UK — Personal Safety Division (service and support contact) UK
- Foster Industrial UK
- Jendco Safety Supply US
- MTO Battery US
- OSI Batteries US
- Premier Welding UK
- Rapid Welding UK
- The Face Mask Store (TFMS) UK
- USA Face Mask Store US
- Welder Supply US
- Weldfabulous US
- Welding Supplies Direct (WASP) UK
- WeldTech UK
No listed suppliers for this region — see the supplier directory.
See the full supplier directory for all regions and evidence notes.
Listing ≠ endorsement. Confirm availability, approval status and source evidence before purchase or regulated workplace use.
Note
Not a consumable Table 2 SKU but a reusable diagnostic accessory used to confirm minimum air flow and the low-airflow alarm function. This record's tier is "manufacturer-listed" (appears by part number throughout the manual's official inspection procedure) rather than "officially-approved", since it is not on the NIOSH approval label itself. No dedicated "diagnostic tool" category exists in the schema, so filed under "other".