I18N Interface traduite automatiquement. Les données des pièces, les spécifications et les éléments de preuve restent en anglais ; la version anglaise fait foi.

SEC 01 // FICHE SYSTÈME

Optrel e3000 / e3000X PAPR

Verified against primary source · 2026-07-04 current

Optrel's belt-mounted PAPR (three airflow settings, 170–240 l/min, HEPA 99.8% at 0.3 micron, up to 18 h battery). The e3000X is the current blower; the original e3000 and its 10-hour battery are discontinued. Confirmed on Optrel's own product page: "the Swiss Air face mask cannot be attached to the e3000x blower."

Classe d'homologation

Approval standards, classes and regions
StandardClassRegion
EN 12941TH3UK/EU
NIOSH 42 CFR 84approved (label-specific configuration)US
Avertissement générations et numéros de pièce : e3000 (discontinued, 10-hour battery) superseded by e3000X (18-hour battery 4553.020). Backward compatibility of the 4553.020 with the older e3000 blower is distributor-confirmed only — not yet found in an Optrel manual or DoC.

Têtes de protection compatibles

Pièces dans notre base de données

Parts recorded for this system with category and compatibility status
Numéro de piècePièceCatégorieStatut de compatibilité
4553.020 e3000X Battery (18-hour) battery T2 Manufacturer-listed part

Sources de la fiche

Evidence — dated sources
  1. [01] optrel.us manufacturer page Live-verified on Optrel USA's official e3000X page: TH3 (EN 12941), NIOSH-approved, up to 18 h battery, 170–240 l/min, HEPA 99.8% at 0.3 micron, compatible-hood list as recorded, and the explicit statement that the Swiss Air face mask cannot attach to the e3000X blower. 2026-07-04
  2. [02] optrel.us manufacturer page Battery 4553.020 (up to 18 h, $231.93); page names only the e3000X — e3000 backward compatibility remains distributor-evidenced. 2026-07-04